AC blowing warm air
Likely cause
Low refrigerant, dirty condenser coil, or failed compressor contactor.
Our fix
Leak search, weigh-in charge, or contactor replacement.

When your AC quits on a 90° afternoon, you don't have hours to spare. Our vans stock the most common parts, so most repairs are diagnosed and fixed in one visit — with flat-rate pricing agreed to before we start.
Six issues make up the majority of Philly AC breakdowns. Each one has a known cause and a known fix — no guesswork, no diagnostic fees when you approve the repair.
Likely cause
Low refrigerant, dirty condenser coil, or failed compressor contactor.
Our fix
Leak search, weigh-in charge, or contactor replacement.
Likely cause
Clogged filter, frozen evaporator coil, or a failing blower motor / capacitor.
Our fix
Filter swap, defrost + airflow correction, or blower motor / cap replacement.
Likely cause
Clogged condensate drain line or cracked drain pan.
Our fix
Vacuum drain line, treat with tablets, or replace pan.
Likely cause
Failing dual-run capacitor or debris in the fan blade path.
Our fix
Test capacitor microfarads and replace within spec; clear debris.
Likely cause
Shorted compressor, seized fan motor, or under-sized breaker.
Our fix
Amp-draw test, isolate short, and replace the failed component.
Likely cause
Low charge or restricted airflow starving the coil.
Our fix
Thaw safely, replace filter, then leak-test the refrigerant circuit.
The outdoor unit has a pull-out disconnect on the wall. Confirm it's fully seated and the 30–60A double-pole breaker in the panel is on.
Set the mode to COOL and drop the set-point 3–5° below room temperature. Replace batteries if the screen is dim.
A blocked 1" filter can freeze the coil in under an hour. Swap it and give the system 30 minutes to defrost before re-testing.
If the insulated copper line at the outdoor unit is iced over, shut the AC off and run FAN ONLY for 60 minutes so the coil can thaw before we arrive.
Every quote is presented on the tablet before any wrench is turned. Prices below are Philadelphia-area ranges for parts + labor on a standard residential split system.
Diagnostic fee
Waived when you approve the repair the same day.
| Repair | Range |
|---|---|
Capacitor replacement Most common no-cool call in July / August. | $185 – $325 |
Contactor replacement Pitted contacts cause intermittent starts. | $210 – $360 |
Condensate pump / drain clear Prevents water damage to ceilings below the air handler. | $175 – $295 |
Blower motor (ECM) Weak airflow, especially on 2nd floor rooms. | $650 – $1,150 |
Refrigerant leak search + repair Includes electronic leak detection and weighed-in charge. | $450 – $1,400 |
Compressor replacement Often the point where replacement makes more sense than repair. | $1,800 – $3,600 |
Nights, weekends, and holidays — no extra dispatch fee for members of our Comfort Club plan.